Modular circuit breakers

Thermal-magnetic and residual current circuit breakers, modular and residual current switches of the Xpole series, made in Grombalia under Eaton licence.

Thermal-magnetic circuit breakers

Disjoncteurs divisionnaires PLN6

Disjoncteurs divisionnaires PLN6

  • High-quality 1-pole + N circuit breakers (1 module wide) for small installations
  • Red / green status indicator
  • Cage terminal with wire guide
  • Many accessories can be fitted later
  • Rated currents up to 40 A
  • Tripping curves B and C
  • Rated breaking capacity 6 kA (IEC/EN 60898)
Disjoncteurs divisionnaires PLSM / PLZM

Disjoncteurs divisionnaires PLSM / PLZM

  • High selectivity towards upstream fuses thanks to low let-through energy
  • Busbar and profile compatibility with the other devices of the Xpole series
  • Screw and cage connection terminals (bi-connect)
  • Busbar connection from the top or bottom, leaving the cage terminals free
  • Meets insulation coordination requirements — contact gap > 4 mm
  • Red / green contact position indicator
  • Tripping curves B, C and D
  • Rated currents up to 63 A

Rated voltage 250 V (per pole), T = 4 ms. Mind the polarity!

Disjoncteurs divisionnaires PLS6 / PLZ6

Disjoncteurs divisionnaires PLS6 / PLZ6

  • High selectivity towards upstream fuses thanks to low let-through energy
  • Busbar and profile compatibility with the other devices of the Xpole series
  • Screw and cage connection terminals (bi-connect)
  • Busbar connection from the top or bottom, leaving the cage terminals free
  • Meets insulation coordination requirements — contact gap > 4 mm
  • Red / green contact position indicator
  • Tripping curves B, C and D
  • Rated currents up to 63 A

Rated voltage 250 V (per pole), T = 4 ms. Mind the polarity!

Residual current circuit breakers

Disjoncteurs différentiels PBLSM / PBLS6

Disjoncteurs différentiels PBLSM / PBLS6

  • Operation independent of the mains voltage
  • Combined with a PLS circuit breaker, the assembly becomes a residual current circuit breaker
  • Rated current 40 and 63 A
  • Many variants thanks to the wide choice of ratings and tripping curves of the PLS breakers
  • Wide range of accessories that can be fitted later on the PLS breaker
  • Type A: sensitive to pulsating DC residual currents
  • Type G: reliable protection against nuisance tripping
  • Type S: selective residual current protection (type AC for S versions, type A for S/A versions), recommended for installations with downstream surge arresters
Disjoncteurs différentiels PKNM / PKN6

Disjoncteurs différentiels PKNM / PKN6

  • Tripping independent of the mains voltage
  • Busbar and profile compatibility with the other devices of the Xpole series
  • Screw and cage connection terminals (bi-connect)
  • Busbar connection from the top or bottom, leaving the cage terminals free
  • Wire guide for safer wiring
  • Toggle (breaker part) in the colour of the rated current
  • Red / green mechanical status indicator
  • Many accessories can be fitted later
  • Type A: protection against pulsating DC fault currents
  • Type G: 10 ms tripping delay to avoid nuisance tripping (during thunderstorms, for example)

These devices protect people and property against earth fault currents, without the overload protection having to operate (EN 61008-1, §1).

Modular switches

Interrupteur modulaire ZP-A

Interrupteur modulaire ZP-A

  • Compliant with IEC/EN 60947-1, -3
  • Number of poles: 1, 2, 3, 3N
  • Ratings: 25 A, 40 A, 63 A

Residual current switches

Interrupteurs différentiels PKFM / PFIM

Interrupteurs différentiels PKFM / PFIM

  • Busbar and profile compatibility with the other devices of the Xpole series
  • Red / green mechanical status indicator
  • Busbar connection from the top or bottom
  • Many accessories can be fitted later
  • Type AC